Calculation of neutron fluence to dose conversion factors for extremities

  • 25 Pages
  • 1.36 MB
  • 7257 Downloads
  • English

Pacific Northwest Laboratory, Available to the public from the National Technical Information Service , Richland, Wash, Springfield, VA
Neutron flux -- Health aspects -- United States., Extremitries (Anatomy) -- Effect of radiation on -- United States., Neutrons -- Measurement., Radiation dosim
StatementR.D. Stewart ... [et al.] ; prepared for U.S. Department of Energy, Assistant Secretary for Environment, Safety, and Health, Office of Health.
ContributionsStewart, R. D., United States. Dept. of Energy. Assistant Secretary for Environment, Safety, and Health. Office of Health., Pacific Northwest Laboratory.
The Physical Object
FormatMicroform
Paginationxi, 25 p.
ID Numbers
Open LibraryOL14698911M

Part of this effort requires the calculation of neutron fluence-to-dose conversion factors for finger and wrist/ankle extremities. This study focuses on conversion factors for two types of extremity models: (1) the polymethyl methacrylate (PMMA) phantom (as specified in the draft standard for performance testing of extremity dosemeters) and (2 Cited by: 5.

Calculation of neutron fluence to dose conversion factors for extremities. Richland, Wash.: Springfield, VA: Pacific Northwest Laboratory ; Available to the public from the National Technical Information Service.

MLA Citation. Stewart, R.

Description Calculation of neutron fluence to dose conversion factors for extremities FB2

and United States. Department of Energy. Assistant Secretary for Environment, Safety, and Health. The DOELAP free-field calibration geometry and a realistic glovebox scenario are simulated using a Monte Carlo neutron and photon transport code.

Calculated DOELAP and RSD extremity fluence-to-dose equivalent conversion factors for the free-field calibration geometry are 1 to 9 percent lower than the calculated whole-body conversion : Annmarie Ruth Wood-Zika. Page 4 DOSE PER FLUENCE CONVERSION FOR NEUTRONS To understand the response of instrumentation and interpret shielding calculations, one needs to connect the neutron fluence**, Φ (cm-2), with a dosimetric quantity such as E.

However, the amended 10 CFR Part does not continue to provide a table of values of PE, the effective dose per fluence. Calculations of conversion coefficients from fluence to ambient dose equivalent, along the principal axis of the ICRU sphere, have been performed for neutron energies between keV and 10 MeV, using the Monte Carlo transport code MCNPX.

The results obtained are compared with those of other authors and ICRP The standard fluence-to-dose conversion factors in ANSI/ANS are based on a so-called dose equivalent (DE) formula, where the absorbed dose is modified by a quality factor, Q, which is equal to 1 for gamma rays and varies from 1 to 20 for neutrons.

can easily be calculated from the neutron emission rate as follows: Fluence rate = total neutron emission rate 4π x Calculation of dose equivalent from fluence The mean neutron fluence. equivalent conversion factors as a function of incident neutron energy and (for the personal dose equivalent) of the angle of incidence, a, with respect to the normal of the front surface, as calculated in [76].

Download Calculation of neutron fluence to dose conversion factors for extremities FB2

From top to bottom: a = 0, 15, 30, 45, 60 and 75°. Coefficients de conversion de la fluence vers l'équivalent de dose ambiant (trait. Dose conversion factors Fluence to dose equivalent factors are given in Fig.

for photons [9], neutrons [10], muons [11], protons and pions [12]. These factors can be used for converting particle fluence to dose for personnel protection purposes. Accelerator-induced activity. a Absorbed dose in rad equal to 1 rem or the absorbed dose in gray equal to 1 sievert.

(c) If it is more convenient to measure the neutron fluence rate than to determine the neutron dose equivalent rate in rems per hour or sieverts per hour, as provided in paragraph (b) of this section, 1 rem ( Sv) of neutron radiation of unknown energies may, for purposes of the regulations in this part.

Abstract. Various segments of the health physics community advocate the use of different sets of neutron fluence-to-dose equivalent conversion factors as a function of energy and different methods of interpolation between discrete points in those data sets.

to ultrahigh energy neutrons transport and interactions in the matter. The high energy neutrons are pointed as the component that contribute about 70% of the neutron effective dose that represent the 35% to 60% total dose at aircraft altitude.

In this research calculations of conversion coefficients from fluence to effective dose are. For neutrons whose mean energy equals to MeV, the effective dose per fluence is obtained from the curve in Fig.

This curve has been plotted from the data of table of the effective dose per fluence for mono-energetic neutrons in the CD accompanying with ICRP report. Get this from a library. Calculation of neutron fluence to dose conversion factors for extremities.

Details Calculation of neutron fluence to dose conversion factors for extremities FB2

[R D Stewart; United States. Department of Energy. Assistant Secretary for Environment, Safety, and Health. Office of Health.; Pacific Northwest Laboratory.;]. The fluence to organ-dose and effective-dose conversion coefficients for neutrons and protons with energies up to GeV was calculated using the PHITS code coupled to male and female adult reference computational phantoms, which are to be released as a common ICRP/ICRU publication.

2MeV) has become a priority. Here it is necessary to consider dose equivalents to organs deeper than the skin [1]-[2]. There have been many studies to obtain conversion factors for effective doses of neutrons and photons with human phantoms and Monte Carlo code [3]-[7].

For electrons there are some data using the ICRU sphere. Intended for use by shield designers to calculate whole-body dose rates to radiation workers and the general public, this standard presents flux-to-dose rate conversion factors for neutrons (x10/sup -8/ to 20 MeV) and gamma rays ( to 15 MeV).

Definitions used are based on ANS-9. neutron fluence-to-dose conversion factor Elsayed K. Elmaghraby et al Developments of the Monte-Carlo Code PHITS for the Heavy-ion Transport Calculation Koji Niita et al-On the decision making criteria for cis-lunar reference mission scenarios Samy El-Jaby et al-This content was downloaded from IP address on 06/05/ at fluence-to-effective dose conversion coefficients were then derived from the obtained organ doses and the radiation weighting factor, w R, and the tissue weighting factor, T, following the instruction given in ICRP III.

Results and Discussion 1. Fluence-to-dose conversion coefficient The calculated fluence-to-effective dose conversion. ICRP‐60 tissue weighting factors were used for the calculations. Photon doses were measured in phantom for all beam energies.

Neutron spectra were measured for and and ICRP‐74 quality conversion factors used to calculate ambient dose equivalents. The ambient dose equivalents were corrected for each tissue using neutron depth dose data from.

Neutron Fluence Rate • The intensity of a neutron source is usually described by the fluence rate • This is often and incorrectly referred to as the flux • Neutron dose rate: mrem/hr at 1 m/Ci uSv/hr at 1m/GBq • Gamma dose rate: mrem/hr at 1 m/Ci uSv/hr at 1m/GBq. neutrons, the incident number of neutrons per square centimeter equal to 1 rem may be estimated from table Sievert (Sr) Neutron Flux Dose Equivalents.

neutrons per square. Average flux to deliver. Neutron energy. centimeter equivalent to a. mrem in 40 hours. dose of 1 rem (neutrons. Results showed that the experimental value of the neutron fluence-to-dose conversion factor is ( ± ) Gy cm over the whole energy spectrum of the fission neutrons from ETRR-2 reactor.

Infrared investigation proved the effectiveness of UV-absorption in PADC detector for neutron monitoring purposes. The conventionally true neutron dose rates are then determined using the appropriate fluence-to-dose equivalent conversion coefficients at several reference positions. This report describes the impact on calculated neutron dose rates of switching from NCRP to ICRP neutron flux-to-dose equivalent rate conversion factors.

Neutron Fluence – What is Fluence. In nuclear engineering, we have to distinguish between the neutron flux density, the neutron intensity and the neutron fluence. Neutron fluence, previously referred to as the neutron dose, is defined as the time integral of the neutron flux density, expressed as number of particles (neutrons) per cm n fluence is primarily defined for material.

When evaluating neutron fluence for shielding considerations, the NCRP recommends measuring the neutron fluence with a closed jaw configuration to maximize neutron production. 24 Mao et al. found that the total number of neutrons produced in the accelerator head is a maximum when the jaws are closed, but the current study found that the dose.

Input the current dose-rate and the desired dose-rate and the thickness of the shield required will be calculated for you. Other common, expensive computer codes do not perform that calculation. The shielding calculations use the latest coefficients from NIST (see references).

Results showed that the experimental value of the neutron fluence-to-dose conversion factor is ( ± )×10−11 Gy cm2 over the whole energy spectrum of the fission neutrons from ETRR The typical whole-body badges used for assessing personnel neutron doses are designed to allow interpretation of (whole body) dose equivalent using conversion factors for limited sources that are contained in ISO ; they do not address neutron extremity/shallow dose.

If neutrons are a concern in a particular situation, the assessment of the. Conversion of Units 4 – 7 Constants 7 - 8 Rules of Thumb 8 - 16 Units and Terminology 17 Radiation Interactions 18 Public Radiation Dose Rates 19 Radon Facts 20 Biological Effects of Radiation 21 Dosimetry 22 - 24 Equivalent Dose, Effective Dose, and Committed Effective Dose 25 Radiation Weighting Factors 26 Calculating TODE and TEDE.

2. Calculations of absolute neutron and gamma flux spectra Calculation methods Most of the calculations were done according to the 3D flux synthesis method but in two ver-sions. In the first, the 3D flux of an energy group g is synthesized using Φ (R,Θ) Φ(R,Z) Φ(R,Θ,Z) Φ(R,Θ) 1 g g g D g = ⋅.Neutron spectra were measured for and and ICRP‐74 quality conversion factors used to calculate ambient dose equivalents.

The ambient dose equivalents were corrected for each tissue using neutron depth dose data from the literature. The depth corrected neutron doses were then used as a measure of the neutron component of the ICRP protection.For neutron fluence, you need to know the primary knock on atom (PKA) spectum as input to SRIM.

PKA spectra per neutron can be obtained from NJOY. Check out my recent work for further details.